Services

Services

Our Core Focus: Conductive Concrete Earthing

We lead the industry with modern, maintenance-free Conductive Concrete Earthing systems—proven to deliver stable, low-resistance performance for decades. In an age where Coal & Salt methods are rapidly becoming obsolete, we offer a safer, smarter, and long-term solution for grounding.

Whether it’s a telecom site in rocky terrain, a solar power plant in dry soil, or a critical substation in a metro city, our solutions are designed to perform under any condition—with:

  • <1 Ohm resistance

  • 30–50 year lifespan

  • Zero corrosion

  • No chemical leaching

  • No recurring maintenance (No Water, No refilling, No replacement )

We Undertake

Outcome: 

An average soil resistivity values on the basis of readings at the site, and recommendations on the basis of the rod depth insertion possible and measurement taken by ERT machine.

Soil Resistivity Testing

Purpose: To understand the electrical characteristics of the soil and build the foundation for accurate earthing system design.

What we do

    • Conduct on-site soil resistivity measurement using the (Wenner four-pin method or E.B.Curdt’s  method) to measure resistivity at various depths.

    • Record data at multiple locations across the site to capture soil stratification and seasonal variability.

    • Analyse readings and average out soil resistivity for the site, which predicts how current will dissipate in the ground.

    • Document all test setups, readings, calculations, and site photos for traceability.

Design and Recommendation

Purpose: To design an earthing system that achieves the target earth resistance value safely, efficiently, and cost-effectively.

What we do

  • Perform design calculations based on soil resistivity data, site load details, and safety standards (IEEE 80 / IS 3043 / IEC 60364).

  • Determine the type, size, quantity, and layout of earthing electrodes (vertical rods, earth mats, rings, or grids).

  • Where natural soil resistivity is high, recommend use of conductive concrete to lower resistance.

  • Provide a full design drawing (plan and cross-section) with expected resistance value and bill of materials.

A doctor consulting with a patient in an office, discussing a medical chart.
Outcome: 

A technically validated earthing layout and material recommendation tailored to your site conditions and desired resistance value required.

Outcome: 

After supply of material, manpower is put on job for excavation, boring at site and pre-castd or fresh casted Conductive concrete earthing electrode is fully installed and after curing period , testing and it ready for operation.

Supply, Installation, Testing & Commissioning

Purpose: To install the designed system with quality workmanship and validate its electrical performance.

What we do

  • Supply all approved materials: copper/galvanized electrodes, conductive backfill, clamps, strips, Pit Cover/ chambers, etc.

  • Execute earth pit excavation, electrode driving, jointing/welding, and backfilling with conductive materials as per design.

  • Perform quality checks during installation: electrode alignment, depth, connections, and bonding.

  • Conduct commissioning tests: fall-of-potential test, earth continuity test.

  • Ensure proper tagging, labelling, and site restoration after completion.

Final Report Submission and Warranty Certificate

Purpose: To provide documented evidence of compliance, safety, and long-term assurance.

What we do

  • Prepare a comprehensive final report including:

    • Soil resistivity test data and analysis

    • Design drawings and calculations

    • Material specifications and test certificates

    • Installation photographs and as-built layouts

    • Commissioning test results and measured earth resistance values

  • Issue a Warranty Certificate covering:

    • Performance of conductive backfill/concrete materials (as per manufacturer warranty)

A diverse team collaborating on digital marketing strategies at a desk, using laptops and tablets.
Outcome: 

A complete documented record of your earthing system and a formal warranty for peace of mind.

What Differentiate Us from Others ??

Advanced Conductive Concrete Technology
(CC Earthing)
  • Unlike Coal & Salt, our CC Earthing uses conductive concrete backfill that:
  1. Doesn’t dissolve, wash away or decay
  2. Offers permanent low-resistance path
  3. Is effective in dry or rocky soil conditions
  • Achieves <1 ohm resistance reliably without depending on moisture

Edge over competitors: We are providing a scientifically engineered solution — not just a product.

Long-Term Value vs. Short-Term Fixes
  • Our system lasts 30–50 years, as opposed to 3–8 years with traditional and conventional methods.
  • No need for frequent maintenance, water pouring, or pit digging again.

Edge over Competitors: Lower total cost of ownership (TCO), greater peace of mind for mission-critical installations (telecom, solar, hospital, IT, etc.)

Close-up of hands holding a pot with soil and a young mint plant in growth.
Environmental and Compliance Friendly
  • No leaching of salt/chemicals into soil
  • Meets or exceeds IS:3043 standards and other global standards like IEEE 80
  • Safe for Enviroment (Not impact plants and trees, Doesnot pollute water and soil as it is Non Chemical)

Edge over CompetitorSave Trees, Save Soil and Save Water . Only product which is Future-ready solution, especially as pollution & soil degradation regulations tighten. 

Basic Requirements of an Effective Earthing System
 
To truly serve its purpose, a grounding system must meet these technical and performance standards:
1. Low and Stable Earth Resistance
  • Target value: <1 ohm (preferably <0.5 ohm in sensitive installations like data centers, substations).
  • Traditional methods often fail to maintain low resistance over time due to soil drying or material degradation.
2. Longevity / Lifespan
  • Expected lifespan: >30 years with minimal maintenance.
  • Coal & Salt systems often fail within 3–5 years due to corrosion and leaching.
3. Corrosion Resistance
  • Materials should be non-corrosive or protected to avoid current-carrying capacity degradation over time.
4. Consistent Performance in All Soil Conditions
  • Especially in rocky, sandy, or high-resistivity soils where traditional methods are ineffective.
In Comparison with Others

Parameter

Our Offering

Typical Competitors

Solution Approach

Scientific, engineered, and site-specific

One-size-fits-all product push

Experience & Expertise

12+ years with industrial, commercial, and residential grounding

Limited experience or focused only on supply

Product Quality

Certified conductive concrete from international manufacturers

Local products, often untested or uncertified

Service Coverage

Design ➝ Supply ➝ Installation ➝ Testing ➝ Commissioning

Mostly supply-only or outsourced installation

Compliance & Safety

Meets international standards (IEEE/IEC) and prioritizes electrocution prevention

Compliance is optional or secondary focus

Post-Installation Support

Scheduled testing, maintenance, and performance audits

Rarely offer ongoing support or warranty coverage

“Why Conductive Concrete Earthing Sets Us Apart”

Designed for decades of operation, conductive concrete earthing resists corrosion, chemical attack, and seasonal soil shifts. Minimal inspection and upkeep are required, cutting downtime and replacement costs. For projects aiming for long term ROI, it offers a reliable, durable, worry free solution.

SUSTAINABLE EARTHING SOLUTION

Does not require water & charcoal, chemical  on regular  interval as it is required in Traditional (Salt and Charcoal) or Conventional (Pipe, Plate, PIP etc) or  chemical earthing. It is found practically that other earthing resistance value increase over time while Conductive Concrete earthing resistance values start decreasing overtime. We have got Performance Certificate to prove the  Maintenance-Free for 50+ Years.

NO LEACHING IN SOIL

Traditional (Salt and Charcoal) or Conventional (Pipe, Plate, PIP etc) or  chemical earthing use material, which is wiped out during heavy rain. It is observed that most of the Electrocution and Fire accident due to short circuit happen during monsoon. Electrically Conductive Aggregate Material is Composition of Carbon/Graphite and when mixed with Cement become solid that is stronger than grade 25 concrete, providing a permanent structure that won’t shrink or wash away.

LOWEST LIFE CYCLE COST 

Conductive Concrete Earthing has lowest life cycle cost when compared to Traditional, Conventional and Chemical Earthing. The life span of Traditional, Conventional and Chemical earthing is 5 to 8 years due to corrosion, while Conductive concrete has lifespan of 50+ years. Taking into consideration the manpower and maintenance for refilling and replacement, it is found that other earthing available are many times costlier than Conductive concrete.

CORROSION FREE EARTHING

Traditional (Salt and Charcoal) or Conventional (Pipe, Plate, PIP etc) or  chemical earthing need water and chemical for ionic conduction, due to which corrosion start happening within few years, while in Conductive concrete earthing conduction is electrical just like in metal and does not corrode at all when compared to other earthing available in the market.

VERSATILE APPLICATIONS

Conductive Concrete Earthing is used for versatile application such as Transformer, Generator, Sub-station, Lifts, Electrical and Telecom Towers, Industrial Buildings, Commercial Buildings, Residential Buildings, Hospitals, Factories, CNC Machines, DCS and Electrical Panel, Solar Projects, for Earthing and Lightening Protection, etc.

STABLE RESISTANCE VALUE

In Earthing, maintaining the resistance value is most critical, which is found neglected in most of the cases. We provide the stable resistance value for lifetime. The material we provide is of International Standard BS EN 62305 for Lightening and BS 7430 for earthing having Permanent & consistent low resistance of 0.001 Ωm